NSN Delivery is your one-stop shop for all the P1-14528 Transformer Power products you require that fall under the NSN 5950-00-816-0263, including those like part number P1-14528 from Magnespec Inc (CAGE Code 53854) (NIIN 008160263). If you are interested in this particular listing, be sure to fill out and submit the RFQ form provided on this page so that you may receive a competitive quote for your comparisons.
To guarantee a solution that meets your unique needs and constraints, we ask that you present us with crucial data like your target price and expected shipping time frame. Once we receive a review of such details, a member of our staff will personally reach out to you in 15 minutes or less to continue the purchasing process.
Note : We Will Not Share Your Information To Any Third Parties.
To make the search for NSN products as simple as possible, we organize our inventory in various ways where you can narrow down results based on a number of parameters. For example, while this product is manufactured by Magnespec Inc, it was specifically produced under the CAGE Code 53854. Additionally, with the NSN 5950-00-816-0263, one can also know that this product belongs to the Federal Supply Class (FSC) 5950 Coils and Transformers.
As such, ensuring that you only procure the exact item you need is made easy. If you are ready to begin, submit a quote request today or give us a call or email at your earliest convenience! We look forward to serving you.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-816-0263 Item PartTypeName: TRANSFORMER,POWER | 5950 | 008160263 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
TS2571 | 6 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.797 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 0.829 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 1.484 INCHES MINIMUM AND 1.516 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.125 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 105.0 DEG CELSIUS |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 7 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.5 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 52.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 6.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; SEVEN SECONDARY WINDINGS,WITH THIRD,FOURTH,AND SEVENTH SECONDARY CENTER TAPPED |
TTQY | TERMINAL TYPE AND QUANTITY | 21 TAB,SOLDER LUG |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.109 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 1.313 INCHES MAXIMUM |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.5 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.5 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 0.006 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 0.009 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 0.009 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 0.009 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |